Collins 180S-1
Jumper Plug Reproduction
A comprehensive engineering design for fabricating reproduction jumper plugs for the Collins 180S-1 antenna tuner — expanded from Rev 1.0 to address all identified omissions: reactive voltage physics, connector identification, matching range analysis, socket wiring traces, fabrication decision flowchart, and period-correct appearance guidance.
▲ What Was Added in This Revision
▼ Contents
- 01Corrections to the Premise
- 02Known vs Assumed Status
- 03Fabrication Decision Flowchart
- 04Circuit Analysis
- 05RF Electrical Requirements
- 06Connector Type & Identification
- 07Verification Procedure
- 08Antenna Matching Range
- 09Dimensional Specification
- 10Parts List
- 11Vendor Sources
- 12Assembly Instructions
- 13Labeling & Period-Correct Appearance
- 14Functional Testing
- 15Operating Without Plugs
- 16Edge Cases & Damaged Sockets
- 17Alternative Approaches
1Corrections to the Premise
Several errors and critical omissions in the standard understanding of the 180S-1 jumper plugs affect both the design approach and the safety of the reproduction. These must be understood before any fabrication work begins.
⚠ Errors & Omissions — Read First
2Known vs Assumed Status
Every significant claim in this document is assigned one of four confidence levels. Read this table before making any purchasing or fabrication decisions.
| Claim | Status | Source / Basis |
|---|---|---|
| Cabinet color is St. James Gray | CONFIRMED | CCA sale listing W1RC; CCA Grey Boxes archive |
| 180S-1 is an S-Line Grey Box | CONFIRMED | CCA historical archives; S-Line Accessories listing |
| C2 = vacuum variable capacitor | CONFIRMED | CCA and universal-radio.com product descriptions |
| L-network is most common mode (no plugs) | CONFIRMED | Collins factory description: “in most cases it is used as an L network” |
| Two jumper plugs, one per socket | CONFIRMED | Multiple community sale listings |
| Plugs are dedicated (SERIES / SHUNT) | PROBABLE | Logical from circuit description; socket labels typical of Collins design practice |
| Connector type is RCA phono | UNCONFIRMED | Engineering inference from Collins S-Line practice — not verified against manual or unit |
| Plugs short tip-to-barrel internally | UNCONFIRMED | Assumed from standard shorting plug design — requires confirmation from schematic |
| Socket labels read “SERIES” and “SHUNT” | UNCONFIRMED | Assumed; exact label text requires manual or unit examination |
| Plug body color / appearance | UNKNOWN | No known photographs of original plugs in community literature |
| Whether both plugs can be installed simultaneously | UNKNOWN | Depends on socket wiring; not confirmed from any source |
3Fabrication Decision Flowchart
Use this flowchart before purchasing any parts. Many 180S-1 users do not need reproduction plugs at all.
4Circuit Analysis
The 180S-1 contains three major passive RF elements: C1 (input shunt capacitor), L1 (roller inductor), and C2 (variable vacuum capacitor). The jumper plugs switch C2 between two circuit configurations by closing pre-wired internal paths in the rear panel sockets.
Three Operating Modes
How the Jumper Plug Works — The Socket Circuit
The jumper plug is purely passive — it shorts two contacts. The routing intelligence is entirely in the chassis wiring at the rear panel sockets. Each socket has two internal terminals; the plug’s tip and barrel short them together when inserted, closing the pre-wired C2 path. Without the plug, the contacts are open and C2 remains isolated.
5RF Electrical Requirements
The jumper plug contacts are in the RF path of a tuner that CCA describes as a 1 kW network. The voltage and current at a jumper socket depend on transmitter power, the antenna’s impedance and which network node the socket is wired to, and that wiring is not yet confirmed (Section 2). The figures below are worked estimates for 1 kW, not Collins specifications.
What Voltage and Current Can a Jumper Socket See?
The 50 Ω input side of the tuner runs at modest RF voltage. The antenna side does not: at a given power the RF voltage rises with the load impedance, and reactive loads and circulating current in the network raise it further. That is why C2 is a vacuum capacitor.
RF Voltage and Current at 1 kW — Worked Estimates
Once fitted, a shorting plug joins its two contacts, so there is almost no voltage across its own insulator; its job is to carry the RF current with low resistance. The voltage stress falls on the open socket when the plug is out and, if the socket shell is not earthed to the chassis, on the whole plug body, which then sits at the RF voltage of that node and must not be touched while transmitting. Which case applies depends on the socket wiring (Section 7).
Requirements Summary
| Parameter | Minimum Requirement | Basis |
|---|---|---|
| Voltage withstand (RF peak) | ≥ 1,500 V_pk wherever any part of the plug can sit above earth | Working figure for 1 kW into moderate loads (estimates above); high-impedance loads can exceed it |
| Current carrying capacity | ≥ 10 A_rms | 1 kW into a 10 Ω load; about 2× the 50 Ω line current |
| Plug resistance, tip to barrel | < 5 mΩ | Thermal limit: P_heat = I² × R < 0.5 W at 10 A. Measure with a four-wire milliohm meter (Section 12) |
| Mated contact resistance | As low as the connector allows | Set by the connector: Switchcraft rates its RCA plug contacts at 0.02 Ω, up to 2 W per contact at 10 A. Keep sockets clean and check for heating (Section 14) |
| Connector body insulation | ≥ 2,500 V DC test | Test margin over the 1,500 V_pk working figure, where the plug body can sit above earth |
| Conductor cross-section | ≥ 1.3 mm² (16 AWG) | Current capacity with thermal headroom |
| Conductor material | Nickel, silver, or gold over copper | Tarnish resistance — oxidised contact = failure at power |
| Dielectric material | PTFE (Teflon) preferred | Voltage withstand + low HF loss tangent; standard RCA plugs use other plastics |
6Connector Type & Identification
The connector type on the 180S-1 rear panel is unconfirmed (see status table, Section 2). The following section gives both the engineering assessment and a visual identification guide for use when examining an actual unit or a clear photograph.
Engineering Assessment — Most Likely Type
| Connector Type | Likelihood | Reasoning |
|---|---|---|
| RCA Phono (IEC 60169-11) | Most likely | Standard Collins S-Line inter-unit RF connector on 51S-1, KWM-2, 75S-3B rear panels; correct era; single-conductor shorting function maps cleanly to tip-to-barrel short |
| Banana / binding post | Possible | Used on some Collins accessories; would require a U-wire jumper rather than a shorting plug body |
| BNC | Possible but unlikely | BNC was less common in Collins S-Line era accessories; bayonet locking is unusual for configuration jumpers |
| PL-259 / SO-239 (UHF) | Unlikely | Too large for a configuration jumper; reserved for main antenna/transmission line connections |
| Proprietary multi-pin | Very unlikely | Collins used standard connectors for simple configuration switching; no evidence of proprietary jumper connector in community literature |
Socket Face Identification Guide
Use a torch and magnifier (or a clear rear-panel photograph) to compare the socket geometry to the diagrams below. Measure the outer diameter of the socket opening if possible.
7Verification Procedure
Complete all steps possible before purchasing parts. Steps 1–3 can be done remotely; steps 4–5 require physical access.
Remote Verification — No Unit Required
- 1Search online photo sources. Search eBay for “Collins 180S-1” and examine rear-panel photographs of listed units. Search the CCA website image archive and the Antique Radio Forums photo threads. Look specifically for the two jumper sockets — compare to the face diagrams in Section 6. A single clear rear-panel photo can confirm the connector type with certainty.
- 2Post to the CCA Reflector ([email protected]). Ask specifically: “Can anyone photograph the rear panel of a Collins 180S-1 showing the two jumper plug sockets close-up?” Owners of complete units can typically respond within days. Request both face-on and angled views. Ask for a ruler or coin in frame for scale.
- 3Purchase the instruction manual reproduction. Surplus Sales of Nebraska, part #COL-180S-1, ~$19. The manual contains rear-panel photographs and the full schematic showing socket labels and wiring. This is the only source that can confirm both connector type AND internal wiring simultaneously.
Physical Verification — With Unit in Hand
- 4Inspect the sockets with a torch and loupe. Compare to the face diagrams in Section 6. Measure the socket opening with digital calipers: RCA ≈ 9.5mm OD; BNC ≈ 14mm; SO-239 ≈ 24mm. Read the socket labels — note the exact label text for both sockets.
- 5Trace the internal wiring from each socket. With the chassis accessible: follow the wire from each socket terminal to its connection inside the chassis. Socket pin 1 (centre contact) and pin 2 (barrel/ground contact) each connect to specific nodes. Sketch the connections: draw a simple diagram showing Socket A pin 1 → [node name], Socket A pin 2 → [node name]. Do the same for Socket B. This tells you what the plug shorting those two contacts will actually do to the RF circuit.
8Antenna Matching Range — Do You Need the Plugs?
Before fabricating reproduction plugs, determine whether your antenna system actually requires C2 in circuit. For many amateur HF antennas, the L-network mode (no plugs) provides fully adequate matching across all bands.
Mode A — L-Network (No Plugs): Typical Matching Range
With C1 as the input shunt capacitor and L1 in series, as this document assumes, the L-network can only transform loads whose series resistance is below 50 Ω up to 50 Ω. L1 also tunes out capacitive load reactance, but the network can absorb only a small inductive reactance (25 Ω at most). The exact range on each band depends on the C1 and L1 values in the 180S-1, which this document has not confirmed; check the instruction manual. This mode typically suits:
- Electrically short verticals and wires, which present low resistance with capacitive reactance
- Coax-fed antennas whose impedance at the tuner has a resistance below 50 Ω
- The original aircraft trailing-wire application, for which CCA notes the 180S-1 was in most cases used as an L network
Mode B — SHUNT C2: When This Mode Helps
Adding C2 in shunt at the output completes the pi network (C1, L1, C2). CCA’s description is that the complete pi circuit is used when the L network cannot match the antenna; its main gain is matching loads whose resistance is above 50 Ω, which the L-network cannot do. This is also the mode in which the antenna side of the network runs at the highest RF voltage (Section 5). This includes:
- End-fed half-wave antennas presenting several hundred ohms or more at the feed point
- Long wires and random-length wires fed near a high-impedance point
- Coax-fed antennas presenting more than 50 Ω resistance at the tuner
- Aircraft trailing wires on certain frequency/length combinations
Mode C — SERIES C2: When This Mode Helps
Adding C2 in series with the antenna puts capacitive reactance in the output arm, so the network can cancel inductive load reactance that L1 alone cannot. The resistance range stays as for Mode A (below 50 Ω). This includes:
- Antennas with large inductive reactance components requiring series capacitive cancellation
- Wires somewhat longer than a resonant quarter-wave, which present low resistance with inductive reactance
- Random-length wire antennas on bands where they look inductive
9Dimensional Specification
Dimensions are for the RCA phono (IEC 60169-11) shorting plug, assuming connector type is confirmed as RCA. All dimensions must be verified against actual 180S-1 sockets before purchasing parts.
| Dimension | Nominal | Tolerance | Notes |
|---|---|---|---|
| Outer barrel OD | 9.5 mm (0.374″) | ±0.2 mm | Must engage socket retention spring |
| Centre pin diameter | 3.175 mm (0.125″) | ±0.05 mm | IEC 60169-11 standard |
| Centre pin protrusion | 7.0 mm (0.275″) | ±0.5 mm | Must reach socket centre contact |
| Overall plug length | 28–32 mm (1.10–1.26″) | ±2 mm | Varies by manufacturer |
| Shorting wire gauge | 16 AWG minimum (1.3 mm²) | — | Current capacity requirement |
10Parts List
Parts for two complete plugs (one SERIES, one SHUNT). Assumes RCA phono connector — verify type first.
| Item | Description | Qty | Specification | Part Numbers |
|---|---|---|---|---|
| P1, P2 | Male RCA phono plug, metal body, no cable strain relief | 2 (+ 1 spare) | Nickel or silver-plated brass body; PTFE insulator preferred where obtainable. Switchcraft 3502-series plugs are rated 250 V AC and 6 A, with plastic insulators: use only where the socket shell is earthed (Section 5) | Switchcraft 3502 |
| W1, W2 | Shorting wire, 16 AWG tinned copper | 5 cm | Tinned or silver-plated copper; no insulation needed inside plug body | Belden 9493 or similar |
| T1, T2 | Heat shrink tubing, clear, 12 mm ID, 3:1 ratio | 4 cm | Rated ≥ 125°C; Raychem DR-25 preferred | TE Connectivity RNF-3000; Raychem DR-25 |
| S1 | Silver-bearing solder, 63/37 or 60/40 | 5 g | Resin-core; silver content reduces contact resistance | Kester 44; MG Chemicals 4900 |
| L1, L2 | Adhesive label, white, permanent, 10×25mm | 2 | Rated ≥ 85°C; permanent adhesive | Brady M21-375-499 or equivalent |
11Vendor Sources
Mouser Electronics
Switchcraft 3502 and Amphenol ACPR series in stock. Search by part number. No minimum. ~$3–4 each. Ships worldwide.
mouser.com ↗DigiKey Electronics
Full Switchcraft and Amphenol connector lines. Same-day dispatch. Search Switchcraft 3502 or Amphenol ACPR-SL.
digikey.com ↗Surplus Sales of Nebraska
180S-1 instruction manual reproduction, part #COL-180S-1, ~$19. Contains rear-panel photographs and schematic confirming connector type and socket wiring. (402) 346-4750.
surplussales.com ↗Nationwide Radio / KE9PQ
Alternative source for 180S-1 manual reproduction with spiral binding and fold-out schematic pages.
ke9pq.com ↗CCA Reflector — [email protected]
Post before ordering parts. Members with complete 180S-1 units can confirm connector type, photograph sockets, and may offer original plugs for copying.
collinsradio.org ↗RF Parts Company
If the vacuum capacitor C2 requires replacement due to arc damage. Verify capacitance range and voltage rating against the 180S-1 instruction manual before ordering.
rfparts.com ↗12Assembly Instructions
Tools Required
- Temperature-controlled soldering station at 350°C
- Needle-nose pliers; wire strippers for 16 AWG; flush-cut cutters
- Heat gun; helping hands or PCB vice
- Ohmmeter (continuity check at every stage)
- Resin flux pen; magnifier or loupe
Step-by-Step Assembly
- 1Disassemble the plug body. Unscrew the barrel from the tip assembly. Inspect both contacts — clean with 99% IPA if tarnished. The centre pin solder cup and the barrel ground contact ring must both be bright metal.
- 2Prepare the shorting wire. Cut 20 mm of 16 AWG tinned copper. Strip 4 mm from each end. Tin both ends with silver-bearing solder — a bright, fully wetted fill on each tip.
- 3Solder wire to centre pin. Apply flux to the centre pin solder cup. Heat cup and wire simultaneously. Flow solder to fill. Joint must be shiny — no cold joints. Allow 30 seconds cool before handling.
- 4Check resistance immediately. Measure pin-to-barrel with ohmmeter. If reading shows OL (open circuit) now, before the barrel is assembled, a joint has failed — find and re-solder before continuing.
- 5Route wire and solder to barrel ground contact. Route so no kinking or strain when assembled. Apply flux. Heat contact and wire simultaneously. Flow silver-bearing solder to fill. Bright, fully wetted joint required.
- 6Inspect both joints under magnification. Look for cold joints (dull/granular), insufficient fill, or solder bridges to adjacent contacts. Reheat and re-flow any suspect joint.
- 7Verify resistance: tip-to-barrel <5 mΩ. With both joints made and before closing: measure tip-to-barrel with a four-wire (Kelvin) milliohm meter. Must read <5 mΩ (0.005 Ω), the Section 5 requirement. An ordinary two-wire multimeter cannot resolve milliohms and only confirms continuity (the plug should read the same as the meter’s shorted leads). Anything above 5 mΩ means a deficient joint.
- 8Slide heat shrink over rear before closing. A 20 mm length of 12 mm heat shrink over the barrel provides strain relief and seals against dust ingress.
- 9Assemble plug body. Thread barrel onto tip assembly and tighten firmly. The barrel-to-body joint is also part of the ground circuit. Apply heat gun to shrink the tubing.
- 10Final resistance check. Measure through the fully assembled connector: tip-to-barrel must still read <5 mΩ. Test mechanical security — barrel must not rotate under hand force. Repeat for the second plug.
13Labeling & Period-Correct Appearance
Functional Labeling
| Plug | Label | Socket | Suggested Colour |
|---|---|---|---|
| Plug 1 | SERIES | SERIES socket on rear panel | Blue label |
| Plug 2 | SHUNT | SHUNT socket on rear panel | Orange label |
Apply a small adhesive label to the heat shrink at the rear of each plug. Cover with clear adhesive tape for durability. Store both plugs in a labelled bag secured to the rear of the unit to prevent loss.
Period-Correct Appearance for CCA-Grade Restoration
The original plug appearance is classified Unknown in the status table — no known photographs of original 180S-1 jumper plugs exist in publicly available community literature. For a CCA-grade restoration, the best approach is:
- First priority: locate an original. Post to the CCA Reflector requesting photographs. If an owner has the original plugs, photograph them for dimensions and appearance before deciding on reproductions.
- For RCA phono reproductions: Collins used nickel-plated hardware throughout the S-Line. A nickel-finish plug such as the Switchcraft 3502 suits the period appearance, within the rating limits in Section 5. Avoid chrome-plated or gold-plated plugs — neither is consistent with Collins S-Line period practice.
- Body length: Keep the plug body compact — a short-body plug is more consistent with the utilitarian Collins accessory aesthetic than a long-body audiophile plug with an extended grip.
- No external identification markings on original plugs — original Collins configuration plugs typically had no printed labels. The socket itself was labeled on the chassis. Reproductions should therefore carry only a small identification tag on the heat shrink rather than marking the plug body itself.
- CCA disclosure: Reproduction plugs must be disclosed as reproductions in any CCA listing. They do not reduce the grade below Very Good if the rest of the unit is grade-appropriate, but must be identified explicitly.
14Functional Testing
Bench Tests Before Installation
- 1DC resistance: Tip-to-barrel resistance <5 mΩ on both plugs, measured with a four-wire milliohm meter (Section 12, step 7). Any reading above 5 mΩ = failed joint, find and re-solder.
- 2High-current bench test (recommended): Pass 5 A DC through the assembled plug for 60 seconds. Monitor for localised heating at solder joints. Any area measurably hotter than ambient after 60 seconds at 5 A indicates a joint that will fail at RF power.
- 3Physical retention: Insert plug into a spare RCA socket or the actual 180S-1 socket (unit unpowered). Plug must seat positively and resist pull with moderate force. Rattle or looseness indicates a socket retention spring problem — not a plug problem.
In-Service Verification (Low Power First)
- 4Verify at 5–10 W CW before any high-power operation. Note L1 and C1 settings at best match with no plug installed (baseline).
- 5Install SHUNT plug. Retune C2 and L1. If match improves or extends to a previously unmatchable load, the plug is working correctly.
- 6Remove SHUNT, install SERIES. Repeat. Each mode should change the tuning parameters noticeably — if both give identical SWR to the no-plug L-network, the sockets may not be wired as expected.
- 7Increase power in stages (25%, 50%, 75%, 100%). Monitor plugs for heat, arcing noise, or unusual smell. Any of these = reduce power immediately and investigate.
15Operating Without the Plugs
See Section 8 for the matching range analysis of each mode and the practical test for determining whether plugs are needed for your specific antenna system.
16Edge Cases & Damaged Sockets
Both Plugs Installed Simultaneously
This scenario is addressed in Section 4. Do not install both plugs until the socket wiring has been traced from the schematic. Without confirmed wiring knowledge, installing both plugs simultaneously could create an unintended short circuit between circuit nodes.
Damaged or Missing Sockets
If the rear panel sockets are damaged, corroded beyond recovery, or entirely absent (removed by a previous owner), the circuit path that the jumper plug would activate may still be present in the chassis wiring — just with a missing entry point. Options:
- Replace the socket. If connector type is confirmed as RCA, replacement Switchcraft 12B RCA panel-mount jacks are available from Mouser and DigiKey. The socket mounts through a standard hole in the rear panel. Replace like-for-like.
- Direct chassis wiring bridge. If socket replacement is not practical, trace the two terminals of each missing socket to their chassis wiring connections. Install a direct short between those two connection points in the chassis wiring to permanently activate the desired C2 mode. This is appropriate only for an operator who knows which mode their antenna requires and does not need to switch.
- External switching. For a flexible modern solution, wire a miniature DPDT RF-rated switch to the socket connections and mount it on the rear panel with a small label. This allows mode switching without the original plug mechanism. Verify switch RF current and voltage ratings against the requirements in Section 5 before installation.
Corroded Sockets
Socket contacts that are tarnished but mechanically intact can be treated with DeOxit D5 followed by DeOxit Gold G5, cycling the plug in and out several times. If carbon deposits are present (from a previous arc-over), clean with 99% IPA on a cotton swab. Carbon tracks provide a permanent low-resistance path for subsequent arcing at reduced power levels — a socket with carbon deposits should be replaced before returning to 1 kW service.
17Alternative Approaches
If Connector Type Is Banana / Binding Post
The jumper becomes a U-wire: 12 AWG bare or tinned copper wire bent into a U, with 4mm banana plugs soldered or crimped to each end. Pomona 1400 or Mueller BU-00 banana plugs are RF-rated and appropriate for this application. The U-wire connects the two binding posts of the respective socket pair.
If Connector Type Is BNC
Use an Amphenol UG-915 or equivalent BNC shorting cap (a male BNC connector with an internal short between centre conductor and body). These are standard items from test equipment suppliers. Verify voltage and current ratings against the Section 5 requirements before use at 1 kW.
Commercial Off-the-Shelf Shorting Caps
RCA shorting caps are sold mainly for audio use. Check the maker’s voltage and current ratings: Switchcraft rates its RCA plugs at 250 V AC working voltage and 6 A, far below the Section 5 working figures, and lists none with PTFE insulators. Treat any shorting cap like the Section 10 plug: confirm the socket wiring first and test at low power before raising it (Section 14). Gold-plated caps are also out of keeping with Collins period practice (Section 13).
3D-Printed Plug Body
A 3D-printed PETG or high-temperature PLA body around the internal contact assembly produces a cosmetically authentic reproduction. The dielectric properties of PETG at HF frequencies are marginal for high-power RF use — verify loss tangent before using at 1 kW. The current and voltage are carried entirely by the internal metal assembly; the printed body provides only physical form and does not carry RF. This approach is most valuable for collectors seeking period-correct appearance rather than engineering performance.
Frequently Asked Questions
Do I need the jumper plugs to use a Collins 180S-1 antenna tuner?
Many Collins 180S-1 owners do not need the jumper plugs, because without them C2 is isolated and the tuner works as an L-network of C1 and L1, which Collins describes as the most common mode. A simple test is to tune your antenna with no plugs fitted; if you reach an SWR of 1.5:1 or better on your operating frequencies, reproduction plugs add no operational benefit and are mainly of cosmetic value for CCA grading.
What connector type are the Collins 180S-1 jumper plugs?
The connector type of the Collins 180S-1 jumper plugs is unconfirmed from publicly available sources, because the BAMA manual is image-only. An RCA phono shorting plug is considered the most likely type based on Collins S-Line rear-panel practice, with banana/binding post or BNC possible. Confirm it before buying parts, from the reproduction instruction manual sold by Surplus Sales of Nebraska, from close-up rear-panel photographs, or by asking owners on the CCA Reflector.
How do I make a reproduction jumper plug for a Collins 180S-1?
Once the socket is confirmed as RCA phono, a Collins 180S-1 reproduction jumper plug can be made from a metal-bodied male RCA plug with a short 16 AWG tinned copper link soldered from tip to barrel using silver-bearing solder and finished with heat shrink. The assembled plug should measure under 5 milliohms tip to barrel on a four-wire milliohm meter. Standard RCA plugs such as the Switchcraft 3502 are rated 250 V AC and 6 A, so use one only where the socket shell is earthed.
Are standard RCA plugs rated for use as Collins 180S-1 jumper plugs at 1 kW?
Not on their ratings alone. Switchcraft rates its RCA plugs, including the 3502 series, at 250 V AC working voltage, 500 V AC dielectric withstanding voltage and 6 A, while a Collins 180S-1 at 1 kW can see about 1,400 V peak on the antenna side into a 1,000 ohm load and over 3,000 V into 5,000 ohms. A fitted shorting plug has almost no voltage across its own insulation, so an RCA plug is only reasonable where its shell is earthed through the socket; otherwise keep power low.
Can both jumper plugs be installed in a Collins 180S-1 at the same time?
Do not install both Collins 180S-1 jumper plugs at once until the socket wiring has been traced from the schematic, because the effect is unknown. If the SERIES and SHUNT sockets are wired to different nodes, fitting both could create an unintended short in the RF path, possibly shorting the antenna terminal to ground. After fitting any reproduction plug, test at 5–10 W first and raise power in stages while watching for heat, arcing noise or unusual smell.