Rebuilding & Upgrading the Collins S-Line
70K-2 Permeability-Tuned Oscillator (PTO)
Component Renewal · Calibration & Stability · RFI Mitigation · Ferrite Core Techniques
Table of Contents
- Introduction & Scope
- Theory of PTO Operation
- Common Failure Modes & Aging Issues
- Tools & Test Equipment Required
- Disassembly Procedure
- Cleaning & Mechanical Restoration
- Capacitor Replacement
- Resistor Replacement
- Valve and Diode Replacement
- Ferrite Core RFI & Noise Mitigation
- Shielding & Grounding Improvements
- Reassembly Procedure
- Alignment & Calibration
- Full Bill of Materials
- Performance Verification & Expected Results
- Conclusion
- References
1. Introduction & Scope
The Collins Radio 70K-2 Permeability-Tuned Oscillator (PTO) is the beating heart of the entire S-Line receiver and transceiver family. It is the primary frequency-determining element in all ten models covered by this whitepaper — the 75S-1, 75S-2, 75S-3, 75S-3B, 75S-3C/m receivers, the 32S-1, 32S-2, 32S-3 transmitters, and the KWM-2/KWM-2A transceivers. In each application the 70K-2 tunes a 200 kHz range of about 2.5–2.7 MHz which, mixed with the 2.955–3.155 MHz variable IF and combined with band-switched crystal injection, produces the final tuned receive or transmit frequency.
Collins Radio designed the 70K-2 to remarkable standards for its era, achieving frequency stability and mechanical precision that still commands respect more than six decades later. However, time is not kind to any analogue oscillator. After sixty-plus years, the fixed mica capacitors in the tuned circuit (notably C302 and C303) can drift or develop internal faults, the small 0.02 µF bypass and coupling capacitors can become temperature-sensitive, and the 1N34 sideband-shift diode can become leaky and cause warm-up drift. The precision leadscrew and tuning mechanism may suffer from hardened lubricant and worn bearing surfaces. In addition, today’s shacks are full of switching power supplies, computers and SDR peripherals that the original designers never had to consider.
This whitepaper provides a systematic procedure for the mechanical and electronic restoration of the 70K-2 PTO, together with optional measures for modern RFI environments:
- Component renewal — replacing the documented problem parts (C302, C303, the 0.02 µF bypass capacitors and the 1N34 diode) with stable equivalents, while leaving the temperature-compensating capacitors alone unless one is proved faulty.
- Mechanical restoration and alignment — cleaning and relubricating the drive, then resetting calibration and end-point spread.
- RFI mitigation — applying ferrite common-mode suppression to the external supply and output leads where local noise is a problem.
The 70K-2 is a valve oscillator. Its oscillator valve (V301), tuning coil and fixed capacitors are housed in the PTO’s aluminium box and wired point-to-point, using mica, polystyrene and small bypass capacitors; it contains no electrolytic capacitors and no printed circuit board. Solid-state replacement PTOs are outside the scope of this paper.
2. Theory of PTO Operation
2.1 Permeability Tuning Principle
Unlike a conventional variable-capacitor VFO, the 70K-2 achieves frequency change by varying the effective inductance of its tank coil through the mechanical movement of a ferromagnetic (powdered iron) slug inside the coil former. As the slug is advanced into the coil by the precision leadscrew mechanism, the effective permeability of the coil core increases, raising the inductance and lowering the resonant frequency of the LC tank. As the slug retracts, permeability decreases, inductance falls, and resonant frequency rises.
This is the fundamental advantage of the PTO over a variable-capacitor VFO: the tuning element is a linear motion mechanism (leadscrew and nut), which can be made extremely precise and repeatable. In the 70K-2 the leadscrew moves the slug through a 200 kHz range of about 2.5 to 2.7 MHz (the CCA’s KWM-2/2A description gives 2.5–2.7 MHz; DJ7HS measured one unit at 2.4967–2.7085 MHz), and the tuning is linear enough that Collins specified 1 kHz calibration accuracy, 200 Hz visual dial accuracy and backlash of no more than 50 Hz for the KWM-2.
2.2 Oscillator Circuit Architecture
The 70K-2 is a Colpitts-type oscillator built around a single valve, V301, mounted on a socket inside the PTO box. The main tuning coil, L303, is resonated by fixed mica capacitors including C302 (1000 pF) and C303 (3000 pF), and the tuned circuit is coupled to V301 through C304 (about 200 pF in the unit DJ7HS serviced). Temperature-compensating capacitors C301, C305 and C311 offset the drift of the coil and slug. The 0.02 µF capacitors C306, C307, C309 and C310 are bypass and coupling capacitors. L302 sets the end-point spread, and T301 is a small clip-in coil. The output goes to the radio’s mixer through a short coaxial lead.
Diode CR301, originally a 1N34, and trimmer C308 form the sideband-shift circuit: CR301 switches C308 across C303 so that the PTO moves by the spacing of the two BFO crystals (about 2.7 kHz) when the sideband is changed, keeping the dial calibration correct on both sidebands.
2.3 Frequency Allocation by Model
The 70K-2 tunes the same 200 kHz range, about 2.5–2.7 MHz, in every covered model. In the receivers it mixes with the 2.955–3.155 MHz variable IF to produce the 455 kHz IF; in the transmitters it mixes with the 455 kHz SSB signal to produce the variable IF; the transceivers do both. The end points are set by the L302 spread adjustment and the brass stop collar on the shaft, not by fixed end-stop screws.
Model |
PTO Frequency Range |
Application |
IF / Injection Point |
|---|---|---|---|
75S-1 / 75S-2 | 2.5–2.7 MHz | Receiver VFO | Second mixer: 2.955–3.155 MHz variable IF to 455 kHz |
75S-3 | 2.5–2.7 MHz | Receiver VFO | Second mixer: 2.955–3.155 MHz variable IF to 455 kHz |
75S-3B | 2.5–2.7 MHz (2.50135–2.70135 MHz on LSB; about 2.7 kHz lower on USB, AM and CW) | Receiver VFO | Second mixer: 2.955–3.155 MHz variable IF to 455 kHz |
75S-3C/m | 2.5–2.7 MHz | Receiver VFO | Second mixer: 2.955–3.155 MHz variable IF to 455 kHz |
32S-1 / 32S-2 | 2.5–2.7 MHz | Transmitter VFO | Mixes with the 455 kHz SSB signal to give the 2.955–3.155 MHz variable IF |
32S-3 | 2.5–2.7 MHz | Transmitter VFO | Mixes with the 455 kHz SSB signal to give the 2.955–3.155 MHz variable IF |
KWM-2 | 2.5–2.7 MHz | TX/RX VFO | Shared: 455 kHz ↔ 2.955–3.155 MHz in both directions |
KWM-2A | 2.5–2.7 MHz | TX/RX VFO | Shared: 455 kHz ↔ 2.955–3.155 MHz in both directions |
3. Common Failure Modes & Aging Issues
After six decades of service, the 70K-2 exhibits several predictable failure modes. Understanding these before disassembly helps you recognise what you are dealing with and avoids missing a defect during inspection.
3.1 Capacitor Failure
- Fixed mica tank capacitors (C302, C303): DJ7HS traced a PTO whose whole range had shifted up by about 30 kHz, and whose frequency jumped with supply voltage, to an internal fault in C302 (1000 pF); a new dipped mica part cut the supply sensitivity from about 50 Hz/V to about 2 Hz/V. C303 (3000 pF) sets calibration and must be a precision dipped mica part.
- Bypass and coupling capacitors (C306, C307, C309, C310, 0.02 µF): aged parts can become temperature-sensitive; one CCA author could cause several kilohertz of drift just by cooling and heating them.
- Temperature-compensating capacitors (C301, C305, C311): these set the PTO’s designed temperature compensation and are generally stable. Leave them alone unless one is shown to be faulty.
- Sideband-shift trimmer (C308): may be locked with lacquer; DJ7HS found one that could not be adjusted until it was cleaned and freed.
3.2 Resistor Drift
The PTO’s carbon-composition resistors (R301–R303) should be measured. DJ7HS found them within tolerance in one unit and left them in place; replace only those that have drifted out of tolerance.
3.3 Valve and Diode Ageing
- Oscillator valve (V301): Emission falls with age. A weak valve can make the oscillator slow to start, reduce its output or make it more sensitive to supply voltage. Test it on a calibrated valve tester and replace it with a good valve of the type listed in your radio’s instruction book.
- Sideband-shift diode (CR301, 1N34): Old 1N34s sometimes become leaky with age and cause noticeable warm-up drift.
3.4 Mechanical Issues
- Dried leadscrew lubricant: The original grease hardens and becomes abrasive over decades, increasing friction and tuning backlash.
- Stiff tuning: A CCA author traced stiff tuning to a misadjusted pinch drive at the main shaft, adjusted through the oblong bushing.
- Worn brass nut: The captive brass nut that rides the leadscrew can wear and develop a loose fit, causing erratic tuning near band edges.
- Slug contamination: Ingressed moisture causes the powdered-iron slug to oxidise and expand, sometimes jamming it in the coil former. Never apply force — chemical penetration is the correct remedy.
- Loose or corroded bearing surfaces: The sleeve bearings at either end of the leadscrew corrode and develop axial play, contributing to dial backlash and frequency hysteresis.
3.5 Ingressed Electromagnetic Interference
Modern shacks contain switch-mode supplies, USB peripherals and LCD drivers. Noise from them can reach an S-Line receiver by several paths — the antenna and feed line, the mains wiring and the interconnecting cables — and the PTO’s supply and output leads are only one possibility. It shows as a raised noise floor or birdies at fixed frequency offsets. Identify the path before modifying anything; Section 10 describes optional ferrite measures for the PTO leads.
4. Tools & Test Equipment Required
4.1 Mandatory Tools
- Temperature-controlled soldering station — 350 °C tip, 0.5 mm or 0.8 mm conical tip
- Solder sucker (vacuum desoldering pump) or desoldering braid (Chemwick 1.5 mm)
- Digital multimeter with capacitance, frequency, and diode-test modes
- LCR meter (100 kHz and 1 MHz measurement capable) — e.g., DE-5000 or equivalent
- Fine watchmaker’s screwdrivers — flat 1.0 mm, 1.5 mm; Phillips #00
- Non-metallic alignment tool (Collins type 490-3654-000 or equivalent nylon hex)
- Magnification — 3× loupe minimum; jeweller’s headband at 5× preferred
- Anti-static wrist strap and ESD-safe mat
- Small dental pick set for lead-clearance and flux removal
- 90% isopropyl alcohol (IPA) and fine brushes for flux residue removal
- Soft lint-free cloth and cotton swabs
4.2 Recommended Test Equipment
- Frequency counter — 1 Hz resolution at 2.5–2.7 MHz (e.g., GPSDO-referenced counter)
- Oscilloscope — 20 MHz bandwidth minimum for output waveform inspection
- Current-limited variable B+ supply (about 150 V DC) and a 6.3 V heater supply, for bench testing the PTO out of the radio — observe high-voltage precautions
- Spectrum analyser or SDR with software spectrum — for noise floor and phase noise assessment
- Tube tester — calibrated mutual conductance type (Hickok 600A or equivalent) for the PTO valve
5. Disassembly Procedure
- Power down and discharge. Switch off the S-Line equipment, unplug from mains, and wait a minimum of five minutes. Verify B+ supply capacitors have discharged below 10 V using your multimeter on the highest DC voltage range before touching anything.
- Record the starting point. Before any work, note the dial reading against an accurate reference at a few points (for example 0, 100 and 200 on the dial) so that the effect of the rebuild can be judged.
- Remove the PTO from the radio. Remove the cabinet and follow the instruction book for your model to release the PTO from the chassis and from its dial drive. Note how the dial and PTO shaft are coupled before separating them, so the calibration can be restored.
- Disconnect the output lead. The PTO output is a short coaxial lead to the radio’s mixer circuit (on the 32S-3 it is a white coax to a terminal behind the frequency-control switch). Label it before disconnecting it.
- Disconnect the supply leads. Photograph or sketch the B+ and heater connections before disconnecting them.
- Open the PTO box. Remove the back cover. The internal assembly — valve socket, wiring, capacitors and coils — comes out as one wired bundle. Handle it gently: the leads on L303 and on the small coil T301 are fragile, and one CCA author broke both.
- Photograph everything. Before touching any component, take high-resolution photographs of the wiring from several angles, the lead dress and the coil assembly. These photographs are your restoration map.
- Remove and test the valve. Pull V301 straight out with even pressure and test it on a calibrated valve tester.
6. Cleaning & Mechanical Restoration
6.1 Leadscrew and Bearing Cleaning
The leadscrew must be cleaned of all hardened lubricant before relubricating. Apply penetrating oil (Kroil or equivalent) sparingly to the leadscrew threads and allow 30 minutes penetration time. Then use cotton swabs dampened with IPA to remove the softened grease. Avoid acetone or MEK near any plastic or phenolic parts. Once clean, visually inspect the thread profile under magnification — the threads should be crisp and uniform with no galling or flattening.
Re-lubricate with a very small quantity of Nye Lubricants Rheolube 716A or equivalent non-hardening precision instrument grease. A toothpick applied trace along two threads is sufficient. Excess lubricant contaminates the coil assembly and must be avoided. The sleeve bearings at each end of the leadscrew should be cleaned with IPA and lightly oiled with Nye Lubricants NyeTorr 6000P or equivalent low-outgassing instrument oil — one drop per bearing, worked in by hand rotation.
6.2 Coil Former and Slug Inspection
Inspect the coil former (the phenolic or PTFE tube carrying the tank inductance winding) for cracks, moisture staining, and contamination. If the coil winding itself shows signs of oxidation on the silver-plated wire, carefully clean with a dry cotton swab — do not use IPA directly on the winding as it may weaken the coil former adhesive.
Inspect the powdered-iron slug for cracking, chipping, or oxidation staining. If the slug turns freely and smoothly throughout its full range of travel without binding, it is mechanically sound. If it is stuck, apply a single drop of penetrating oil at the gap between the slug and the former wall, wait 15 minutes, then try again. Never force the slug — powdered-iron slugs are brittle and cannot be repaired if cracked.
7. Capacitor Replacement
7.1 Selection Philosophy
A 70K-2 rebuild is not a blanket recap. The PTO is remarkably forgiving, and its temperature-compensating capacitors were chosen to balance the drift of the coil and slug, so replacing them with different parts upsets the designed compensation. Replace the documented problem parts — C302, C303, the 0.02 µF bypass capacitors and the 1N34 diode — and any other part that measurement shows to be faulty.
7.2 Tank Capacitors (C302, C303)
Replace C303 only with a high-accuracy 3000 pF dipped mica capacitor, 5% or better, ideally 1–2%. A CCA author found that a 2700 pF substitute shifted either end of the dial calibration by several kilohertz, and that ceramic substitutes drift badly. Some schematics show 2000 pF for C303, which that author believes is a typo. C302 is a 1000 pF mica; DJ7HS cured a 30 kHz shift and frequency jumps by replacing a faulty C302 with a new 1000 pF dipped mica part.
7.3 Temperature-Compensation Capacitors
Leave C301, C305 and C311 alone unless one is proved faulty. A temperature-compensating capacitor has a deliberate temperature coefficient chosen to offset the coil and slug, so an NP0/C0G (zero-coefficient) ceramic is not an equivalent, and fitting NP0 parts in these positions would upset the designed compensation. If one must be replaced, match the original value and temperature characteristic from the Collins parts list.
7.4 Bypass and Coupling Capacitors (0.02 µF)
The 70K-2 contains no electrolytic capacitors. Its 0.02 µF bypass and coupling capacitors (C306, C307, C309, C310) can become temperature-sensitive with age. A CCA author replaced them with high-stability 0.022 µF, 630 V parts (Mouser 146-630V.022K); DJ7HS replaced them with 22 nF ceramics in his unit and saw no change, so treat this as preventive work rather than a guaranteed cure for drift.
Ref |
Original |
Function |
Replacement |
Notes |
|---|---|---|---|---|
C301 | 20 pF mica | Temperature compensation | Leave in place | Not an NP0 position |
C302 | 1000 pF mica | Tank | 1000 pF dipped mica | DJ7HS fault: 30 kHz shift, frequency jumps |
C303 | 3000 pF mica | Tank (sets calibration) | 3000 pF dipped mica, 5% or better (1–2% preferred) | A 2700 pF part shifts calibration by several kHz |
C304 | About 200 pF | Coupling to V301 | Original value unless faulty | Value affects output level and frequency |
C305 | 100 pF mica | Temperature compensation | Leave in place | Not an NP0 position |
C306, C307, C309, C310 | 0.02 µF | Bypass / coupling | 0.022 µF 630 V (e.g. Mouser 146-630V.022K) | Preventive replacement |
C308 | Trimmer | USB/LSB shift | Clean and free if locked | Reset shift to about 2.7 kHz |
C311 | — | Temperature compensation | Leave in place | Not an NP0 position |
CR301 | 1N34 | Sideband-shift switch | 1N4148 or 1N4454 | Raises idle frequency about 300 Hz; realign |
8. Resistor Replacement
Measure R301–R303 and replace only those out of tolerance, using metal-film resistors of the same value and an adequate power and voltage rating. Metal-film resistors have lower noise and better long-term stability than carbon composition, but in a sound unit the originals can stay: DJ7HS found them within tolerance and left them in place.
9. Valve and Diode Replacement
9.1 Oscillator Valve (V301)
Fit only a known-good, tested valve of the type listed in your radio’s instruction book. The Collins PTO is sensitive to valve condition: a weak valve can cause the oscillator to fail to start, run at reduced output, or pull with supply-voltage variations. If supply sensitivity remains high with a good valve, suspect C302 (Section 7.2).
9.2 Sideband-Shift Diode (CR301)
Replace a leaky 1N34 with a 1N4148 or 1N4454 silicon diode. The silicon diode’s lower capacitance raises the idle frequency slightly (DJ7HS measured about 300 Hz), which is taken up when the end points are reset. Afterwards, check the USB/LSB shift and reset it with trimmer C308 to the BFO crystal spacing of about 2.7 kHz.
10. Ferrite Core RFI & Noise Mitigation
10.1 Why Ferrite Suppression Works
The 70K-2 PTO is a narrowband, high-Q resonant circuit operating at about 2.5–2.7 MHz. Its susceptibility to external interference is not primarily from conducted RF signals near its operating frequency — those are rejected by the narrow tank selectivity — but from common-mode noise injected on the supply and output cables. Common-mode noise (noise that travels on all conductors of a cable simultaneously, relative to chassis ground) can couple into the oscillator circuit through the supply and output leads.
A ferrite choke (a common-mode choke, not a differential-mode inductor) presents high impedance to common-mode current at the frequencies of interest — typically 100 kHz to 30 MHz for switching power supply noise, and DC to 1 GHz for broadband digital hash — while presenting essentially zero impedance to the differential-mode signal (the supply current, or the 2.5–2.7 MHz oscillator signal on the coax). This is the key physical insight: ferrite common-mode suppression is a free lunch — it suppresses noise without attenuating the wanted signal.
The material choice for the ferrite is critical. For maximum suppression in the range 1–30 MHz (the primary concern for S-Line installations near computers and SDR equipment), Fair-Rite Mix 31 (MnZn, µ = 1500) or Fair-Rite Mix 43 (NiZn, µ = 800) are the optimal choices. Above 30 MHz (digital clocks, USB), Fair-Rite Mix 61 (NiZn, µ = 125) is more effective. Use both materials in series for broadband suppression.
10.2 Power Supply Line Filtering
Outside the PTO, where the supply leads leave it, thread the entire supply bundle (B+, heater and return conductors) through a Fair-Rite 2631803802 snap-together EMI suppressor (Mix 31, #31 material, suited for 5–50 MHz). Pass the cable through three times to achieve a 3-turn winding and multiply the impedance by 9 (impedance scales as N²). At 10 MHz, a single-turn through a #31 bead provides approximately 150 Ω; three turns provides approximately 1350 Ω — sufficient to break any common-mode current path at reasonable noise levels.
Do not add filter networks or electrolytic capacitors inside the PTO. The 70K-2 has no printed circuit board and no electrolytics; its supply bypassing is done by the 0.02 µF capacitors described in Section 7.4, so keep any added filtering outside the PTO, on the external leads.
10.3 Output Coaxial Cable Suppression
The output coaxial cable from the PTO to the mixer injection point can act as an antenna for broadband noise, via shield current flowing back to the PTO ground. The remedy is a common-mode choke on the output coax, placed as close to the PTO housing as possible — ideally within 5 cm of the PTO output connector.
Wind 5 turns of the output coax through a Fair-Rite 2631540002 toroid (Mix 31, OD 22.9 mm, ID 13.7 mm, height 9.0 mm). At 10 MHz this provides approximately 4000 Ω of common-mode impedance while the characteristic impedance of the coaxial cable (and hence the 2.5–2.7 MHz differential-mode signal) is completely unaffected. Fix the coax winding in place with a small cable tie — vibration loosening is the primary failure mode of toroid coax chokes.
10.4 Ferrite Component Selection
Part Number |
Material |
Form Factor |
Application |
Impedance @ 10 MHz |
|---|---|---|---|---|
Fair-Rite 2631803802 | Mix 31 | Snap-bead, 3T wound | Supply leads, outside the PTO | ~1350 Ω (3T) |
Fair-Rite 2643002402 | Mix 43 | Axial bead, on lead | B+ lead, outside the PTO | ~300 Ω (1T) |
Fair-Rite 2631540002 | Mix 31 | Toroid OD 22.9 mm | Output coax choke, 5T | ~4000 Ω (5T) |
Fair-Rite 2661000201 | Mix 61 | Axial bead, on lead | USB / VHF digital hash | ~85 Ω @ 100 MHz |
Amidon FT-50-43 | Mix 43 | Toroid OD 12.7 mm | Alternate output choke, 7T | ~2800 Ω (7T) |
11. Shielding & Grounding Improvements
11.1 PTO Housing Integrity
The aluminium housing of the 70K-2 must make solid, low-impedance contact to the chassis at multiple points to function as an effective Faraday shield. Inspect the mating surfaces between the PTO housing and the chassis deck for oxidation, paint overspray, or corrosion that would increase contact resistance. Clean mating surfaces with 400-grit sandpaper followed by IPA until bright bare aluminium is exposed. Apply a light coating of Sanchem NO-OX-ID A Special electrical contact grease to inhibit future oxidation before reassembly. The mounting screws should be tightened to the point where the housing does not rock on the chassis surface — do not overtighten as the aluminium housing threads are easily stripped.
11.2 Output Connector Ground
The shield connection of the coaxial output lead at the PTO should be inspected for ground continuity to the PTO housing. Many units exhibit a ground resistance of several ohms at this junction due to oxidation. This breaks the shield continuity of the output cable and allows noise current to enter the oscillator through the shield. Clean the connection, apply NO-OX-ID grease where appropriate, and remake it. Verify ground resistance below 0.5 Ω between the coax shield at the far end of the output cable and the PTO housing using your multimeter on the milliohm or resistance range.
11.3 Additional Internal Shielding
For extreme RFI environments (the PTO is operated near an active SDR receiver, in a vehicle with modern electronics, or near industrial switching equipment), an additional layer of copper foil shielding can be applied inside the PTO’s back cover. Use 0.05 mm self-adhesive copper foil tape (available from guitar electronics suppliers or Mouser Electronics). Line the inside of the back cover with copper tape, ensuring good contact to the housing walls. Connect the inner surface of this copper lining to the PTO ground at one point (using a short length of solid copper wire) to prevent the tape from acting as a resonant cavity. Do not ground both ends of the copper lining — one-point grounding is the correct technique.
12. Reassembly Procedure
- Verify all replaced components. Before reassembly, check every replacement against your notes and photographs, and confirm that the temperature-compensating capacitors (C301, C305, C311) are the originals or exact equivalents.
- Clean all flux residue. Use 90% IPA and a fine stiff brush (old toothbrush) to remove all solder flux from the wiring and tag strips. Allow complete drying — minimum 30 minutes — before refitting the cover. Flux residue inside the PTO box can absorb moisture and cause frequency instability.
- Reinstall the valve. Insert V301 with gentle, even pressure, with its pins aligned to the socket. Do not force it.
- Refit the internal assembly. Slide the wired assembly back into the box slowly and evenly, without forcing it or straining the leads of L303 and T301. If you feel resistance, stop, withdraw slightly, and retry.
- Refit the back cover. Tighten its screws evenly so the box is not distorted.
- Fit the optional supply-lead ferrite. Thread the supply leads through the Fair-Rite snap-bead three times, outside the PTO, then snap the bead closed and secure it with a cable tie.
- Fit the optional output choke. If the output lead is long enough, wind 5 turns of it through the Fair-Rite Mix 31 toroid within 5 cm of the PTO and secure the winding with a cable tie.
- Reconnect supply and output leads. Reconnect the B+ and heater leads per your original photographs, and the output lead to its terminal.
- Refit the PTO to the chassis. Restore the dial-to-shaft relationship you noted, refit the mounting hardware, and check ground continuity between the PTO housing and the chassis with your multimeter.
13. Alignment & Calibration
13.1 Initial Power-Up
Connect a frequency counter or calibrated SDR to the PTO output through a high-impedance probe or a small coupling capacitor, so the measurement does not load the oscillator. The 70K-2 output is not a 50 Ω port, and terminating it in 50 Ω changes its operating conditions. Power up and allow at least 10 minutes’ warm-up before any measurements, and longer for final checks: DJ7HS found one unit took about an hour to settle fully.
13.2 Oscillation Verification
Check the output with an oscilloscope and a ×10 probe. The output is several volts peak-to-peak (DJ7HS measured about 6.6 V p-p into a 75 Ω bench load at 150 V DC); compare with the level given in your radio’s instruction book rather than a fixed figure. If there is no oscillation, check the heater and B+ voltages and the valve first, then C302, C303 and C304.
13.3 End-Point Calibration and Spread
Calibrate against an accurate reference, for example by zero-beating a known carrier at a dial point (one CCA procedure for the 32S-3 sets the dial to 100 with a carrier at 3900 kHz on the 3.8–4.0 MHz band). The end-point spread is set with L302, and the end-point stop with the brass collar on the shaft, which lets the stop be set about 6.5 kHz beyond each end of the 0–200 dial range. Follow the instruction book for your model; the accuracy of this adjustment depends on C303 being the correct value.
13.4 Tracking Verification
After setting the end points, check tracking across the range against the reference, for example at every 25 kHz dial point. Collins specified 1 kHz calibration accuracy for the KWM-2; errors well beyond that point to a tank capacitor of the wrong value, a contaminated slug or a mechanical problem.
13.5 Thermal Stability Assessment
Allow the equipment to cool to room temperature. Power up, note the frequency at mid-range (dial 100) and monitor it for at least 30 minutes, recording every 5 minutes. A good unit typically shows warm-up drift of less than 200–300 Hz, and under about 500 Hz is probably good enough (CCA). Larger drift points to a faulty mica capacitor (C302/C303), an ageing 0.02 µF bypass capacitor or a leaky 1N34; a frequency that moves with supply voltage points to C302 or the valve.
14. Full Bill of Materials
Qty |
Reference |
Description |
Suggested Part |
Source |
|---|---|---|---|---|
1 | C303 | 3000 pF dipped mica, 5% or better (1–2% preferred) | Mouser 5982-19-500V3000 (5%); Surplus Sales CSM003000R00GGA (2%) or CSM003000R00JGA (5%) | Mouser / Surplus Sales |
1 | C302 | 1000 pF dipped mica (replace if faulty) | Dipped mica, 5% or better | Mouser / Surplus Sales |
4 | C306, C307, C309, C310 | 0.022 µF 630 V bypass / coupling | Mouser 146-630V.022K | Mouser |
1 | CR301 | Silicon switching diode (replaces 1N34) | 1N4148 or 1N4454 | Mouser / Digi-Key |
1 | V301 | Oscillator valve of the type listed in the instruction book, tested | NOS or tested used | Valve suppliers |
1 | FB1 | Mix 31 snap-bead EMI suppressor (optional) | Fair-Rite 2631803802 | Mouser / Digi-Key |
2 | FB2–3 | Mix 43 axial bead on the B+ lead (optional) | Fair-Rite 2643002402 | Mouser / Digi-Key |
1 | T1 | Mix 31 toroid OD 22.9 mm, output coax choke (optional) | Fair-Rite 2631540002 | Mouser / Digi-Key |
1 | — | Nye Lubricants Rheolube 716A precision grease, 5 ml | Rheolube 716A | Digi-Key / direct |
1 | — | Sanchem NO-OX-ID A Special, 1 oz | NO-OX-ID A-Special | Mouser / hardware |
1 | — | Self-adhesive copper foil tape, 0.05 mm × 25 mm (optional extra shielding) | 3M 1181 Copper Tape | Mouser / Digi-Key |
15. Performance Verification & Expected Results
15.1 What to Expect
A 70K-2 rebuild is mainly about frequency stability and calibration. Any change in the receiver noise floor is likely to be small; judge it by measuring minimum discernible signal on your own unit before and after the work rather than expecting a set figure.
15.2 Frequency Stability
Monitor the PTO output frequency for a full 2-hour operating session against an SDR or frequency counter. Published experience gives these benchmarks:
- Warm-up drift of less than 200–300 Hz is typical of a good unit; under about 500 Hz is probably good enough (CCA).
- Collins specified stability within 100 Hz after warm-up for the KWM-2.
- Units that drift 2 kHz or more, or take an hour or longer to settle, need further work on C302, C303, the bypass capacitors or CR301.
15.3 Phase Noise Assessment
If you have a phase-noise test set or a spectrum analyser with phase-noise capability, measure at mid-range (about 2.6 MHz) before and after the rebuild and record the results. Published phase-noise figures for the 70K-2 are scarce, so your own before-and-after comparison is the useful measure.
15.4 RFI Immunity Test
With the equipment tuned to a quiet frequency in the 40-metre band (7.200 MHz region), hold a modern USB device (mobile phone charger, USB hub) within 30 cm of the S-Line chassis. If the noise floor rises or hash is heard, try the ferrite measures in Section 10 and check ground continuity at the PTO housing mounting points, but also check the other entry paths — the antenna feed line, the mains wiring and the station interconnections — since the PTO leads are only one possibility.
16. Conclusion
The Collins 70K-2 PTO is a masterpiece of precision electromechanical engineering that, when correctly rebuilt and aligned, continues to perform at a level that challenges modern synthesised VFOs in practical on-air usage. The techniques described in this whitepaper — replacement of the documented problem parts (C302, C303, the 0.02 µF bypass capacitors and the 1N34 diode), mechanical cleaning and lubrication, careful realignment, and optional ferrite common-mode chokes on the external leads — address the known sources of degradation in aged units.
Ferrite common-mode suppression is a low-cost and fully reversible measure for the modern shack, with its switching power supplies, SDR receivers, computers, USB devices and LED lighting that the valve-era designers never had to consider. Its benefit depends on how much noise actually arrives on the PTO leads, so measure before and after.
A restored 70K-2 delivers stable, accurately calibrated tuning on SSB, CW and AM. For operators of the KWM-2, KWM-2A and the 32S transmitters, a stable PTO also keeps the transmitted signal where the dial says it is.
This whitepaper draws on published 70K-2 repair experience from the Collins Collectors Association and DJ7HS as well as work at the VK6ADA station and in the r-390a.net community. Corrections, additions, and operating experience from the wider community are always welcome.
17. References & Further Reading
- Collins Radio Company — Service Manual: 75S-3B/C Receiver, Cedar Rapids IA, 1968
- Collins Radio Company — Service Manual: KWM-2A Transceiver, Cedar Rapids IA, 1972
- Collins Radio Company — Assembly Drawing 70K-2 PTO, Engineering Document 390-0196-000
- Collins Collectors Association — 70K-2 Stability Service, collinsradio.org
- Collins Collectors Association — KWM-2/2A Transceiver and 75S-3B equipment descriptions, collinsradio.org
- DJ7HS — A Collins 70K-2 PTO Repair Story and Another Collins 70K-2 PTO Repair Story, qsl.net/dj7hs
- Fair-Rite Products Corp. — Soft Ferrites Data and Applications Handbook, 2021 Edition
- Amidon Corporation — Ferrite Toroid Core Reference Data, rev. 2022
- W. Hayward, R. Campbell, B. Larkin — Experimental Methods in RF Design, ARRL, 2003
- J. Carr — Secrets of RF Circuit Design, 3rd ed., McGraw-Hill, 2001
- Collins S-Line Reflector Archive — r-390a.net Community Technical Reference
- Hollow State Newsletter Archives — Issues 1–53, Dallas Lankford et al., hosted at r-390a.net
- Nye Lubricants — Rheolube 716A Product Data Sheet
- R-390A/URR Pearls of Wisdom — compiled by Chuck Rippel WA4HHG et al., r-390a.net
Frequently Asked Questions
What is the Collins 70K-2 PTO and which S-Line radios use it?
The Collins 70K-2 permeability-tuned oscillator is the primary frequency-determining element in the 75S-1, 75S-2, 75S-3, 75S-3B and 75S-3C receivers, the 32S-1, 32S-2 and 32S-3 transmitters, and the KWM-2 and KWM-2A. It tunes by driving a powdered-iron slug into a coil with a precision leadscrew, raising inductance and lowering frequency, and this linear mechanism gives S-Line dials their precise, repeatable calibration. The oscillator is a Colpitts circuit with a buffered output.
What are the common failure modes of an ageing Collins 70K-2 PTO?
After six decades, common Collins 70K-2 faults are a fixed mica tank capacitor such as C302 or C303 drifting or developing an internal fault, ageing 0.02 µF bypass and coupling capacitors that become temperature-sensitive, and a leaky 1N34 diode causing warm-up drift. Mechanically, the leadscrew lubricant can harden and the drive bind, so check tuning feel and end-to-end tracking as well.
Which replacement capacitors and resistors should be used when rebuilding a Collins 70K-2 PTO?
In a Collins 70K-2, replace C303 only with a high-accuracy 3000 pF dipped mica capacitor, 5% or better and ideally 1 to 2%, as even a 2700 pF part shifts calibration by several kilohertz. Renew the 0.02 µF bypass and coupling capacitors with high-stability types, replace a leaky 1N34 with a 1N4148, and leave the temperature-compensating capacitors alone unless faulty. The PTO sits in a chassis with lethal B+, so discharge the supply first.
How do you align and test a Collins 70K-2 PTO after a rebuild?
Let the rebuilt Collins 70K-2 warm up fully, then check calibration against an accurate reference, for example by zero-beating a known carrier at a dial point, and set the end-point spread with L302 as described in the radio’s instruction book. Use a non-metallic alignment tool, check tracking from end to end, and recheck warm-up drift; excessive drift points to a faulty mica capacitor, an ageing bypass capacitor or a leaky diode.