vk6ada.com.au • SDR Integration Series • Collins KWM-2A Transceiver

Web-888 with the Collins KWM-2A
Integration Options, Station Architecture, and Eight Best-Practice Operating Procedures

The KWM-2A is a transceiver. Every decision about how the Web-888 connects to it flows from that single fact — its TX and RX share one antenna connector, one PTO, one set of band crystals. Unlike a 75S-3 and 32S-3 pair, which transceive through interconnecting cables, the KWM-2A needs no interconnection to keep transmit and receive together, and its ALC is internal unless a linear amplifier is added. What it does have is an internal T/R relay that switches full PA power to the shared antenna connector during transmit, so anything else connected to that antenna path must be protected. This guide covers the three practical integration options and the operating procedures that extract the most value from the Web-888 as a KWM-2A companion.

✍ Mike Peace VK6ADA / r-390a.net and foxtango.org Administrator 📅 March 2026 ⚙ Web-888 • Collins KWM-2A • 455 kHz IF tap • Directional coupler • Web-888 web interface ⚡ Single-PTO advantage • Internal T/R relay protection • TX quality monitor
⚠  PA High Voltage and Transmit Power — Antenna Connector Safety The Collins KWM-2A PA stage operates at approximately 800 V DC plate voltage. During transmit, the KWM-2A’s internal T/R relay connects the PA output to the antenna connector, which then carries the full rated transmit power (~100 W PEP SSB into 50 Ω). Any device connected to the KWM-2A’s antenna connector that is not rated for this power level will be damaged during the first transmit operation. The Web-888’s HF antenna input has a maximum input power rating far below 100 W. If the Web-888 is connected to the KWM-2A’s antenna connector without a specific protection mechanism, it will be destroyed on first transmit. Read Section 2 before making any connections at the KWM-2A antenna connector.

The KWM-2A and the S-Line present different Web-888 integration problems. In the S-Line station, the 75S-3 and 32S-3 are separate units: they transceive when the 32S-3’s selector is set to the receiver’s VFO, and can work split on the 32S-3’s own VFO, so the Web-888 is kept off the shared antenna during transmit. In the KWM-2A station there is only one frequency to manage — the single PTO controls both TX and RX simultaneously, so whatever frequency the dial shows is both the transmit and receive frequency.

What the KWM-2A has instead is the internal T/R relay challenge. Because the KWM-2A’s antenna connector is bidirectional — it is a receiver input during RX and carries full PA power during TX — connecting the Web-888 to the antenna connector without a protection mechanism that tracks the KWM-2A’s internal T/R switching is unsafe. The solution options each have different trade-offs in complexity, cost, and operational capability. This guide ranks them, explains the trade-offs, and then documents the eight operating procedures that apply to whichever approach is selected.

Section 1 — KWM-2A Architecture: What Matters for Web-888 Integration

The Single PTO — the KWM-2A’s Core Advantage Over the S-Line

The Collins KWM-2A uses a single PTO (Permeability Tuned Oscillator) that simultaneously generates the local oscillator frequency for both the receiver section and the transmitter section. When the operator rotates the PTO dial, both the receive frequency and the transmit frequency change identically and instantaneously. There is no separate 32S-3 transmitter to set, no frequency alignment to verify, no possibility of transmitting on the wrong frequency because of a PTO mismatch. The Web-888’s panadapter shows the operating frequency; the KWM-2A transmits on that same frequency automatically.

This single-PTO architecture is the KWM-2A’s most significant operational advantage in a Web-888-augmented station: there is no separate transmit VFO to check. The Web-888 panadapter is never wrong about where the KWM-2A is operating, because there is only one frequency to be wrong about.

The Internal T/R Relay

The KWM-2A’s internal T/R (transmit/receive) relay is the component that manages the share of the antenna connector between the receiver front-end (during RX) and the PA output (during TX). When the PTT is depressed, the relay activates: the receiver front-end is disconnected from the antenna connector, and the PA output is connected. When PTT is released, the relay returns to the receive position.

This relay protects the KWM-2A’s own receiver front-end from the PA output. It does not protect any external device connected to the antenna connector during transmit. Any such device sees the full PA output power during transmit unless it has its own protection mechanism.

KWM-2A Station Companion Units

The KWM-2A is designed to be self-contained for basic operation but is typically paired with:

  • Collins 312B-4 station control — houses a 5 × 7 inch speaker for the receiver audio, a directional wattmeter reading forward or reflected power on 0–200 W or 0–2000 W scales, and a phone patch capable of VOX patch operation. The KWM-2A’s own audio output (up to about 1 W) drives the speaker directly. The 312B-5 version adds an auxiliary VFO for split-frequency operation.
  • Collins 30L-1 linear amplifier — optional; increases output power. If a 30L-1 is in the station, the Web-888 integration must also accommodate the amplifier’s antenna connection and T/R switching. The 30L-1 has its own T/R relay that follows the KWM-2A’s PTT keying; the Web-888 protection architecture must be coordinated with the amplifier’s keying sequence as well.
  • Web-888 SDR — the panadapter and TX quality monitor that this guide addresses.
✎  The KWM-2A vs the S-Line: What Changes in the Web-888 Integration The S-Line Web-888 guide (75S-3 + 32S-3, also at vk6ada.com.au) covers transceive and split operation between two separate units, ALC between the 32S-3 and a linear, and keeping the Web-888 off a shared antenna during transmit. In the KWM-2A everything except the antenna protection is inside one chassis. The KWM-2A guide focuses entirely on the antenna connector protection challenge and the operating procedures that specifically benefit the KWM-2A’s single-operator DX operating style. Both guides address TX quality monitoring via the Web-888 panadapter; this remains the most universally valuable function in any transmitting station context.

Section 2 — Three Integration Options: Comparison and Selection

The Web-888 can be integrated with the KWM-2A in three practical ways. Each provides different capabilities and requires different levels of hardware modification or external equipment. The options are presented in recommended priority order.

◆  Option 1 — IF Tap (Recommended)

A high-impedance buffered tap from the KWM-2A’s 455 kHz IF strip (following the same design principles as the CASCADE-390 kit for the R-390A) feeds the Web-888’s HF input at IF frequency. The Web-888 is set to receive at 455 kHz; a frequency offset in the Web-888’s settings makes the display read the HF frequency.

Pros: The Web-888 never sees the PA output: the tap is inside the transceiver, ahead of the PA, so no external T/R switching is required. The panadapter stays centred on the KWM-2A’s tuned frequency. Best sensitivity (benefits from KWM-2A front-end gain). Note that the 455 kHz IF and mechanical filter are shared with SSB generation, so during transmit the tap sees the exciter signal forming at 455 kHz, usually far stronger than received signals; set the buffer gain and Web-888 input level with that in mind.

Cons: Requires installing an IF tap inside the KWM-2A chassis. The IF tap is a pre-filter tap (before the Collins mechanical filter) for best panadapter bandwidth. During TX the tap shows the 455 kHz exciter signal ahead of the filter and PA, not the transmitted output, so TX quality monitoring still requires a separate approach (Option 2).

Complexity: Moderate. Internal chassis work required. No safety risk if installed correctly following the guide.

◆  Option 2 — Directional Coupler (TX Monitor)

A 30–40 dB directional coupler is inserted in the antenna path after the KWM-2A antenna connector. The coupled port drives the Web-888 HF input through an additional attenuation pad to bring the signal level within the Web-888’s safe input range. The Web-888 continuously monitors the antenna-side signal during both receive and transmit.

Pros: Web-888 sees the transmitted signal during TX (enables real-time TX quality monitoring). No chassis work on the KWM-2A. Works with or without the IF tap (can be combined with Option 1).

Cons: The coupler introduces a small insertion loss on the main antenna path (typically <0.3 dB for a good directional coupler — negligible). Requires calculating the correct attenuation to protect the Web-888 during TX. Attenuation that protects during TX also attenuates the receive signal, potentially reducing Web-888 RX sensitivity.

Complexity: Low to moderate. No chassis work; external connections only. Requires correct attenuator calculation (see Section 6).

◆  Option 3 — Dedicated Monitor Antenna

A separate short receive antenna (1–3 metre random wire, or a small resonant antenna for the primary operating band) is connected to the Web-888 independently of the KWM-2A antenna. The Web-888 receives on its own antenna; the KWM-2A antenna is not shared. During TX, the nearby transmitted signal induces a small voltage in the Web-888’s monitor antenna — well within safe limits at typical separation distances.

Pros: Simplest configuration. No chassis work. No external T/R switching. No attenuation calculation. Web-888 can see TX signal weakly (enough to verify frequency but not for detailed TX quality assessment).

Cons: Monitor antenna will typically be less sensitive than the main antenna (particularly for weak-signal DX work). Panadapter does not benefit from KWM-2A front-end gain. Frequency display must be manually set to match KWM-2A PTO (monitor antenna does not track the PTO automatically).

Complexity: Minimal. A 2-metre piece of wire is sufficient as a monitor antenna in most shack environments.

Which Option to Choose

Priority
Option 1 — IF Tap
Option 2 — Directional Coupler
Option 3 — Monitor Antenna
Panadapter — RX Excellent; tracks PTO, front-end gain, filtered Good; unfiltered wide view; manual alignment needed Adequate; less sensitive; manual alignment needed
TX quality monitor Not available (tap sees the 455 kHz exciter signal, not the transmitted output) Excellent; real-time on-air quality view Limited; enough to verify frequency, not quality
Installation complexity Moderate — chassis work, rear panel BNC Low — external connections only Minimal — one cable
Web-888 protection Inherent — tap is ahead of the PA; check levels on transmit Provided by coupler + attenuator calculation Inherent — physical separation
Recommended for Operators focused on RX panadapter; DX pre-selection; willing to do chassis work Operators focused on TX quality; prefer no chassis work; combine with Option 1 for complete capability Operators wanting basic SDR capability with minimum setup; CW/casual operating
The complete Web-888 capability for the KWM-2A station combines Options 1 and 2: the IF tap provides the RX panadapter that automatically tracks the KWM-2A PTO (for DX spotting and band awareness during receive), and the directional coupler provides the TX quality monitor (for on-air signal assessment during transmit). Both can be installed simultaneously; the Web-888 is switched between them at its input — the IF tap during operating sessions for the panadapter, the directional coupler to assess a transmission. This is the approach used at the vk6ada.com.au station.

Section 3 — Option 1: The IF Tap — CASCADE-KWM Installation

The CASCADE-KWM IF tap follows exactly the same principles as the CASCADE-390 kit for the R-390A, documented in the vk6ada.com.au RX-888 Mk II cascade integration guide. The KWM-2A’s IF chain operates at 455 kHz, the same as the R-390A. A high-impedance buffered tap extracts a sample of the IF signal before the Collins mechanical filter (the pre-filter tap position provides the widest panadapter view, limited by the 200 kHz first-IF passband and the IF circuits ahead of the filter).

The 455 kHz IF offset for the KWM-2A:
When the Web-888 receives the KWM-2A’s 455 kHz IF output, the Web-888’s frequency display must be offset to show the correct HF frequency. The relationship is identical to the R-390A case:

IF offset (Hz) = KWM-2A dial reading (Hz) − 455,000 Hz

Example: KWM-2A tuned to 14.175 MHz → IF offset = 14,175,000 − 455,000 = 13,720,000 Hz (13.720 MHz)

The Web-888’s display then shows 14.175 MHz at the centre of the panadapter, with signals visible at their correct HF frequencies. Since the KWM-2A has only one PTO governing both TX and RX, there is no need to update the offset when moving between TX and RX. Because the tuned signal always sits at 455 kHz in the IF, the offset must be updated whenever the KWM-2A is retuned if the frequency labels are to stay exact; after a small retune the label error is simply the amount retuned. Each band segment is 200 kHz wide (the PTO tunes 2.5–2.7 MHz), so a band change or a move to another segment always needs a new offset.

The IF tap installation inside the KWM-2A chassis follows the same procedure as the CASCADE-390 kit installation:

  • 1
    Power off; discharge B+ below 30 V before any chassis access Measure the B+ bus with a DVM after switch-off. The KWM-2A’s PA plate voltage (approximately 800 V DC) drops through the bleeder network; do not open the chassis until the DVM reads below 30 V. The KWM-2A has less B+ capacitance than the R-390A but the discharge time should still be verified by measurement.
  • 2
    Locate the KWM-2A pre-filter IF tap point from the service manual The KWM-2A service manual identifies the component at the 455 kHz IF input to the Collins mechanical filter. This is the optimal pre-filter tap point. Contact vk6ada.com.au for the current CASCADE-KWM kit documentation which identifies the specific component lead and the connection method for the RG-174 tap lead.
  • 3
    Install the CASCADE-KWM buffer PCB and rear-panel BNC Mount the buffer PCB at a suitable chassis location (typically near the IF section). Drill the rear-panel BNC aperture using a stepped drill bit from outside the chassis. Route a short RG-174 coax from the tap point to the PCB input. Connect the PCB output to the rear-panel BNC. Power the buffer from the B+ supply via a dropping resistor network as specified in the kit documentation. All connections are reversible; no permanent modification to the KWM-2A’s signal path is made.
  • 4
    Verify KWM-2A receives normally; verify Web-888 shows IF signal Power on via Variac. Confirm the KWM-2A receives on all bands with normal sensitivity. Connect a short BNC cable from the rear-panel BNC to the Web-888 HF input. Open the Web-888’s web interface (port 8073 on the shack network), tune it to 455 kHz, and verify that signals appear on the waterfall and shift position as the KWM-2A is tuned. If signals shift correctly, the IF tap is working. Then enter the frequency offset in the Web-888’s settings so the display reads the HF frequency.

Section 4 — Option 2: Directional Coupler for TX Quality Monitoring

The Attenuation Calculation

A directional coupler inserted in the antenna path after the KWM-2A antenna connector samples a small fraction of the transmitted signal. The coupled output must be attenuated to a level safe for the Web-888’s HF input. The Web-888’s maximum safe input power is typically specified around −10 dBm (0.1 mW); confirm from the Web-888 specifications for the specific unit.

Attenuation required (100 W KWM-2A, −10 dBm Web-888 maximum):

KWM-2A PA output: 100 W = +50 dBm
Web-888 maximum safe input: −10 dBm
Required total attenuation: 50 dBm − (−10 dBm) = 60 dB

Recommended configuration: 30 dB directional coupler + 30 dB attenuator pad
or: 40 dB directional coupler + 20 dB attenuator pad

A 30 dB directional coupler + 30 dB N-type or BNC attenuator pad provides exactly 60 dB total attenuation at 100 W input, giving approximately −10 dBm at the Web-888 input — at the safe upper limit. Use a 30 dB coupler + 35 dB pad (or equivalent) to provide a 5 dB safety margin: this gives −15 dBm at the Web-888 input at 100 W PA output.

With a 30L-1 linear amplifier in the chain: if the 30L-1 is in use, the antenna path carries approximately 800 W PEP at its rated output. Recalculate: +59 dBm (800 W) − (−10 dBm) = 69 dB required total attenuation. Use a 40 dB directional coupler + 30 dB attenuator pad (70 dB total, providing 1 dB safety margin). The attenuator must be rated for the power level at its input port; a 30 dB attenuator in the coupler output path sees much lower power than the main line, but the attenuator’s own power rating must still exceed the coupled power level.

Directional Coupler Placement

Place the directional coupler between the KWM-2A antenna connector and the antenna feedline (or the CX-140D T/R switch if one is installed for a 30L-1 keying arrangement). The directional coupler’s main-line ports are in the signal path; the coupled port connects to the attenuator pad and thence to the Web-888. The directional coupler’s main-line insertion loss is typically <0.3 dB for good quality HF directional couplers (Mini-Circuits, Narda, or equivalent) — this loss is negligible for practical operation.

The directional coupler attenuator must be rated for its input power level. A 30 dB directional coupler with 100 W main-line power has approximately 0.1 W (100 mW, +20 dBm) at the coupled port with 100 W PA input. An attenuator rated for 1 W is appropriate and provides a comfortable margin. With the 30L-1 in use at 800 W, the coupled port power rises to approximately 0.8 W (800 mW) for a 30 dB coupler; an attenuator rated for 5 W is appropriate in this case. Verify the attenuator power rating from its datasheet before installation.

Section 5 — Web-888 Band Settings for the KWM-2A

The KWM-2A covers 3.4–5.0 and 6.5–30.0 MHz in 200 kHz segments, each needing its own crystal in the high-frequency oscillator. The KWM-2 was supplied with crystals for the amateur bands (with one 10 m crystal and sockets for two more), and the KWM-2A’s second board takes 14 more. Every band in the table below therefore depends on the crystal fitted for that segment, and the IF tap can show at most that one 200 kHz segment. If both inputs are installed, keep separate settings for the IF tap (Option 1) and the directional coupler (Option 2) — they reach the Web-888 through different inputs.

Band
KWM-2A Coverage
Sideband
IF Tap Display (455 kHz + offset)
Coupler: Tune Web-888 To
IF Tap Span (max.)
80m 3.5–4.0 MHz (one crystal per 200 kHz segment) LSB 455 kHz + offset = 3.75 MHz 3.750 MHz 200 kHz
40m 7.0–7.3 MHz (one crystal per 200 kHz segment) LSB 455 kHz + offset = 7.15 MHz 7.150 MHz 200 kHz
20m 14.0–14.35 MHz (one crystal per 200 kHz segment) USB 455 kHz + offset = 14.175 MHz 14.175 MHz 200 kHz
17m 18.068–18.168 MHz (extra crystal for the 18.0–18.2 MHz segment) USB 455 kHz + offset = 18.118 MHz 18.118 MHz 200 kHz
15m 21.0–21.45 MHz (one crystal per 200 kHz segment) USB 455 kHz + offset = 21.225 MHz 21.225 MHz 200 kHz
10m 28.0–29.7 MHz (one crystal supplied; sockets for two more) USB 455 kHz + offset = 28.500 MHz 28.500 MHz 200 kHz
IF tap offsets and the 455 kHz tuning point. For the IF tap input (Option 1), tune the Web-888 to 455 kHz on every band. The offset changes with the KWM-2A dial reading, so update it when changing bands, and whenever you retune if the frequency labels are to stay exact. The IF tap display column in the table above shows the result for an example frequency in each band; recalculate from the dial reading for any specific operating frequency. For the directional coupler input (Option 2), tune the Web-888 to the HF operating frequency directly — no IF offset calculation is needed.

Section 6 — Eight Best-Practice Operating Procedures for the KWM-2A + Web-888 Station

  • BP
    01
    WARM
    Use the Web-888 Waterfall to Monitor PTO Warm-Up Drift

    The KWM-2A’s PTO drifts during the first 15–20 minutes of operation as the chassis reaches thermal equilibrium. Using the IF tap approach, the Web-888 waterfall shows this drift directly: a known signal (WWV, for example, which can be identified on the waterfall from its time marks) appears as a diagonal trace during warm-up — the trace slopes as the PTO drifts. When the slope flattens, the PTO has stabilised and the station is ready for serious operating. This replaces the informal “warm up for 15 minutes before tuning” discipline with a visible, objective indicator of when the PTO is actually stable. An experienced KWM-2A operator can read the drift rate from the waterfall slope and predict when stabilisation will occur, which is useful for scheduling contacts during warm-up.

  • BP
    02
    DX
    Use the Panadapter for DX Pre-Selection Before Tuning the KWM-2A

    The KWM-2A’s PTO dial is precise within its 200 kHz segment but is not a band-scanning instrument. The operator must tune through the band by ear to identify DX activity. With the Web-888 panadapter showing the IF band content (via the IF tap), signal clusters are immediately visible without audio scanning. A DX station’s pile-up appears as a cluster of peaks on the panadapter; the DX station itself appears as a distinct peak, typically slightly offset from the pile-up cluster in split operation. Identify both the DX frequency and the split-working frequency visually on the panadapter before touching the KWM-2A dial. This approach is faster and more precise than audio scanning and is particularly valuable when looking for weak DX in a noisy band environment.

  • BP
    03
    TXMON
    Monitor Every SSB Transmission on the Directional Coupler Profile for Signal Quality

    The most important single benefit of the directional coupler configuration (Option 2) is the ability to observe the KWM-2A’s transmitted signal on the Web-888 panadapter during active transmission. A correctly operating KWM-2A produces a clean SSB envelope approximately 2.5–3 kHz wide during normal speech, with no significant energy appearing beyond ±3 kHz from the carrier frequency. The ALC system limits the peak drive level so that the signal amplitude varies with speech content but the spectral width remains approximately constant. If the panadapter shows spurious sidebands or abnormal spectral width, investigate the ALC system and drive level settings before continuing to transmit.

    Switch the Web-888 to the directional coupler input before transmitting to monitor your own signal, and back to the IF tap input afterwards to return to the receive-mode panadapter. With both hardware options installed this is a quick change at the Web-888’s input — an external A/B switch, or its second antenna input if used.

  • BP
    04
    SPLIT
    The Single-PTO Limitation in Split-Frequency Operation — Web-888 Awareness

    The KWM-2A’s single PTO means the transmit and receive frequencies are always the same. True split-frequency operation (transmitting on one frequency while listening on another) is not directly possible without additional hardware (a second VFO or a separate receive radio). This is the one significant operational limitation of the KWM-2A relative to modern transceivers for DX pile-up operation.

    The Web-888 panadapter partially compensates: in a DX pile-up where the DX station is listening up (the standard practice), the operator can use the Web-888 panadapter to identify exactly where the DX station is listening by watching where the DX station’s responses occur on the waterfall. The operator then tunes the KWM-2A to that frequency and calls. This is not true split-frequency operation but it is the most informed single-VFO DX pile-up strategy available for the KWM-2A. The panadapter makes it significantly more effective than the traditional “listen around the pile-up by ear” approach.

  • BP
    05
    ALC
    Verifying KWM-2A ALC Operation Via Web-888 Panadapter

    The KWM-2A’s internal ALC system regulates the transmit drive level, keeping the PA within its rated operating envelope and maintaining clean SSB spectral occupancy. The Web-888 panadapter provides a direct visual assessment of whether the ALC is functioning correctly without requiring a separate station monitor or another operator’s report.

    Correct ALC behaviour: during speech transmission, the signal peak on the panadapter rises and falls with speech amplitude but remains approximately 2.5–3 kHz wide at all speech levels. The peak amplitude should vary by approximately 10–15 dB between loud and quiet speech; during pauses between words, the signal should drop to or near the noise floor. If the signal width increases significantly during loud speech (broader than 3 kHz), the ALC is not limiting effectively. If the signal width remains narrow even at peak speech levels but the amplitude is uncharacteristically high, the ALC threshold may be set too high. Either condition warrants investigation of the ALC circuit at the KWM-2A before further operating.

  • BP
    06
    CW
    CW Key Click Assessment via Directional Coupler Profile

    CW key clicks — transmitted sidebands generated by excessively fast RF rise and fall times at the beginning and end of each transmitted element — are visible on the Web-888 panadapter as broadened spectral edges on each element boundary. During continuous CW sending, the Web-888 should show a narrow, well-defined carrier peak that switches on and off cleanly. Broadened edges or splatter sidebands visible on the panadapter indicate key-click problems that should be addressed at the KWM-2A’s keying circuit before competing in environments where spectral cleanliness matters.

    This CW signal quality assessment via the panadapter is available without requiring any other station to monitor your signal and report. The Web-888 directional coupler profile allows the KWM-2A operator to assess their own CW signal quality on any band at any time, which is the most direct available feedback for maintaining good operating practice.

  • BP
    07
    BAND
    Band Change Procedure with Web-888 IF Tap Profile

    When the KWM-2A changes band (selecting a different band crystal), the frequency offset in the Web-888’s settings must be updated to reflect the new operating frequency. The procedure: change band on the KWM-2A; rotate the PTO dial to the desired operating frequency; read the dial; update the Web-888 offset (new offset = new frequency − 455 kHz); verify that the frequency reads correctly by tuning to a known signal.

    For operators who change bands frequently, a written list of offsets for each band segment in use (with the centre-of-segment offset pre-calculated) speeds up band changes. Fine-tune the offset for the specific operating frequency within the segment. This is faster than recalculating the offset from scratch on each band change.

  • BP
    08
    30L1
    Collins 30L-1 Integration — Increased Attenuation Requirement

    If the KWM-2A station includes a Collins 30L-1 linear amplifier, the directional coupler attenuation calculation must be recalculated for the 30L-1’s rated output power (approximately 800 W PEP SSB). As documented in Section 4, this requires approximately 69 dB total attenuation at the Web-888 input for a −10 dBm maximum safe input level. The coupler + pad combination must be rated accordingly, and the attenuator pad must be rated for the power it receives from the coupled port of the directional coupler.

    The 30L-1 also adds a T/R relay in the antenna path that is keyed by the KWM-2A’s PTT. The directional coupler should be placed between the 30L-1’s antenna output port and the antenna feedline (not between the KWM-2A and the 30L-1) so that it monitors the final output including amplifier gain, not the KWM-2A’s exciter-only output. The IF tap (Option 1) is unaffected by the 30L-1’s presence and requires no modification for amplifier integration.

Section 7 — Complete KWM-2A + Web-888 Station Architecture

  ┌──────────────────────────────────────────────────────────────────────────┐
  │   COLLINS KWM-2A + WEB-888 — COMPLETE STATION ARCHITECTURE              │
  │   Combined Option 1 (IF tap) + Option 2 (directional coupler)           │
  └──────────────────────────────────────────────────────────────────────────┘

  KWM-2A INTERNAL ARCHITECTURE (reference for integration context):
  ┌──────────────────────────────────────────────────────────────────────────┐
  │  Single PTO ──────────┬────────────► Receiver LO (RX frequency = TX freq)│
  │  (2.5–2.7 MHz)        └────────────► Transmitter LO (same frequency)     │
  │                                                                           │
  │  Antenna connector ───┬── RX position: → Receiver front-end (sensitive)  │
  │         (SO-239)      └── TX position: ← PA output (~100W / ~800V DC)   │
  │                       (switched by internal T/R relay on PTT)            │
  └──────────────────────────────────────────────────────────────────────────┘

  ─────────────────────────────────────────────────────────────────────────
  OPTION 1: IF TAP (CASCADE-KWM) — panadapter that tracks PTO automatically
  ─────────────────────────────────────────────────────────────────────────

  [KWM-2A IF strip at 455 kHz, pre-filter tap point]
          │
  [CASCADE-KWM buffer PCB] ── powered from KWM-2A B+
          │ 50 Ω BNC output on rear panel
          │ short BNC cable
          ▼
  [Web-888 HF antenna input]
          │ Ethernet → shack network → browser (port 8073)
  [Web-888 web interface — IF tap input]
  Tune to: 455 kHz
  IF offset: (KWM-2A dial reading) − 455,000 Hz
  → Panadapter shows HF frequencies centred on KWM-2A PTO dial reading
  → During TX: tap sees the 455 kHz exciter signal (IF and filter shared)
  → Tap is ahead of the PA; no external T/R switch needed (check levels)

  ─────────────────────────────────────────────────────────────────────────
  OPTION 2: DIRECTIONAL COUPLER — TX quality monitor (external, no chassis work)
  ─────────────────────────────────────────────────────────────────────────

  KWM-2A antenna connector (SO-239)
          │
  [30 dB directional coupler] ──── main line: to antenna / 30L-1 / CX-140D
          │ coupled port: ~0.1W at 100W PA out (+20 dBm)
  [30 dB attenuation pad] ──────── (rated ≥1W; 35 dB for 5 dB safety margin)
          │ ~−15 dBm at Web-888 input (100W PA, 35 dB pad, 30 dB coupler)
  [Web-888 HF antenna input]
  [Web-888 web interface — coupler input]
  Tune to: HF operating frequency directly (no IF offset)
  → Shows transmitted signal on panadapter during TX
  → Shows received signal on panadapter during RX (attenuated)

  ─────────────────────────────────────────────────────────────────────────
  COMBINED CONFIGURATION (both options installed, Web-888 RX input switches)
  ─────────────────────────────────────────────────────────────────────────

  Web-888 has dual antenna inputs (per the maker)
  OR: use an external BNC A/B switch between IF tap output and coupler output
  → Select IF tap input for receive-mode panadapter (DX spotting, band watching)
  → Select coupler input for TX monitoring (signal quality assessment)
  Input selection: external switch OR the Web-888's second input

  ─────────────────────────────────────────────────────────────────────────
  KEY DISTINCTION FROM S-LINE WEB-888 INTEGRATION
  ─────────────────────────────────────────────────────────────────────────
  ┌────────────────────────────────────┬──────────────────────────────────┐
  │  S-Line (75S-3 + 32S-3)            │  KWM-2A                          │
  │  ────────────────────────────────  │  ────────────────────────────── │
  │  Transceive: 32S-3 VFO selector    │  One PTO — always together       │
  │  Separate TX and RX units          │  Single antenna connector — must │
  │  T/R relay keeps Web-888 off ant.  │  protect against internal T/R PA │
  │  Split on the 32S-3's own VFO      │  Web-888 shows drift, band, TX q │
  │  ALC from 32S-3 PA grid (+ linear) │  ALC internal — no cable concern │
  │  Main Web-888 benefit: band view   │  Main benefit: PTO drift + TX mon│
  └────────────────────────────────────┴──────────────────────────────────┘

  ─────────────────────────────────────────────────────────────────────────
  TX QUALITY REFERENCE TABLE (directional coupler profile — what to look for)
  ─────────────────────────────────────────────────────────────────────────
  CORRECT KWM-2A SSB:  ~2.5–3 kHz wide; peaks with speech; null between
                        sidebands; no energy beyond ±3 kHz
  CORRECT KWM-2A CW:   Narrow carrier; clean on/off; no broadened edges
  PROBLEMS:
    Wider than 3 kHz →  ALC not limiting; overdrive; check ALC level
    Residual carrier  →  Balanced modulator null; carrier injection adjustment
    Key-click sidebands → Keying rise/fall time; anti-click network
    Signal off-frequency → KWM-2A PTO mismatch vs calibrated reference
    Constant amplitude  → ALC over-compression; set ALC control lower

Collins KWM-2A + Web-888 station architecture showing Option 1 (IF tap, recommended for receive panadapter) and Option 2 (directional coupler, for TX quality monitoring). Attenuation values shown are calculated for 100 W KWM-2A PA output and a Web-888 maximum safe input of −10 dBm; recalculate for the specific Web-888 variant’s input specification and for use with the 30L-1 linear amplifier. See Section 4 for the 30L-1 calculation. IF offset values must be updated whenever the KWM-2A is retuned if the frequency labels are to stay exact; because the KWM-2A’s single PTO governs both TX and RX, the same offset serves both.

Frequently Asked Questions

Can a Web-888 be connected directly to the antenna connector of a Collins KWM-2A?

No, a Web-888 connected directly to the Collins KWM-2A antenna connector will be destroyed on the first transmission. The KWM-2A’s internal T/R relay protects only its own receiver; during transmit the connector carries the full PA output of about 100 W PEP, far above the Web-888’s input rating. Use an IF tap, a directional coupler with an attenuator pad, or a separate monitor antenna instead.

What are the options for connecting a Web-888 SDR to a Collins KWM-2A?

There are three: an IF tap (CASCADE-KWM) on the KWM-2A’s 455 kHz IF before the mechanical filter, recommended for a receive panadapter centred on the PTO frequency; a directional coupler and attenuator pad in the antenna line, which needs no chassis work and lets the Web-888 monitor transmit quality; and a short separate monitor antenna, the simplest but least sensitive. Combining the IF tap and the coupler gives full receive and transmit capability.

How much attenuation is needed to monitor a Collins KWM-2A transmit signal on a Web-888?

About 60 dB in total for a 100 W Collins KWM-2A and a Web-888 maximum safe input of around −10 dBm, for example a 30 dB directional coupler with a 30 dB pad; a 35 dB pad adds a 5 dB margin. With a 30L-1 amplifier at about 800 W PEP, roughly 69 dB is needed, such as a 40 dB coupler and 30 dB pad, with the coupler placed after the 30L-1 output. Confirm the Web-888’s actual input rating and the pad’s power rating.

Can a Collins KWM-2A work split frequency in a DX pile-up with a Web-888?

Not true split: the Collins KWM-2A’s single PTO always transmits and receives on the same frequency, so genuine split operation needs a second VFO or a separate receiver. A Web-888 panadapter helps by showing on the waterfall where the DX station is answering callers, so the operator can tune the KWM-2A to that spot and call. It is the most informed single-VFO pile-up strategy for the KWM-2A, but not a substitute for split.

References and Notes

  1. Collins Radio Company, KWM-2 / KWM-2A Operating and Service Instructions. Available through the Collins Collectors Association at collinsradio.org and the Virtual Collins Radio Museum (wa3key.com). The service manual is the authoritative reference for the IF circuit tap point location (the component at the 455 kHz IF input to the Collins mechanical filter), the internal T/R relay function, the ALC system description, and the PA plate voltage specification. The IF tap point component designator is identified in the CASCADE-KWM kit documentation available from vk6ada.com.au.
  2. Mike Peace VK6ADA, RX-888 Mk II with the Collins R-390A — Practical Cascade Integration via the CASCADE-390 IF Tap Kit, vk6ada.com.au (March 2026). Primary reference for the IF tap methodology, including the 455 kHz offset calculation formula, the buffer amplifier design principles, the OpenWebRX IF offset configuration procedure, and the pre-filter vs post-filter tap point comparison. The CASCADE-KWM kit for the KWM-2A follows identical design principles to the CASCADE-390 kit documented in that guide; the offset arithmetic transfers directly, although the Web-888 is set up through its own KiwiSDR-style web interface rather than OpenWebRX.
  3. Mike Peace VK6ADA, Web-888 SDR Integration with Collins S-Line 75S-3 and 32S-3, vk6ada.com.au (March 2026). Companion guide for the S-Line station integration. The distinction between the S-Line’s dual-PTO operating discipline and the KWM-2A’s single-PTO architecture is the central differentiator between the two guides; reading both provides a complete picture of Web-888 integration across the Collins S-Line and KWM-2A product families.
  4. Mike Peace VK6ADA, Web-888 Remote Access Setup for Vintage Receivers, vk6ada.com.au (March 2026). Primary reference for Web-888 hardware overview, web interface configuration, network setup (static IP, DDNS, WireGuard VPN), security hardening, and frequency calibration against WWV. The hardware and software foundation documented in that guide is prerequisite to the KWM-2A-specific integration described here.
  5. Mike Peace VK6ADA, Tohtsu CX-140D Use Cases for Collins S-Line, R-388, R-390, R-390A, Hammarlund SP-600 and HQ-180, vk6ada.com.au (March 2026). Reference for the T/R switching configuration applicable to KWM-2A stations equipped with a Collins 30L-1 linear amplifier. The 30L-1 introduces an additional T/R relay in the antenna path; the CX-140D guide’s Configuration A (T/R switching) applies directly to the 30L-1 + KWM-2A station. The directional coupler placement note in BP-08 (coupler after the 30L-1 output, not between the KWM-2A and 30L-1) is consistent with the CX-140D guide’s discussion of amplifier station configurations.
  6. Mini-Circuits and Narda Microwave (and equivalent manufacturers), directional coupler datasheets. The directional coupler specifications referenced in Section 4 (30 dB coupling, <0.3 dB main-line insertion loss, 50 Ω throughout HF frequency range) are typical of high-quality HF directional couplers available from Mini-Circuits, Narda, and equivalent RF component manufacturers. Verify the coupling factor, frequency range (must cover 3.5–30 MHz for all KWM-2A bands), maximum main-line power rating, and coupled port connector type from the specific coupler datasheet before installation. The attenuator pad must be separately specified and verified for its power rating at the coupled port power level.
✍ Mike Peace VK6ADA  /  r-390a.net and foxtango.org Administrator  •  March 2026 vk6ada.com.au — Collins Radio Technical Resource